Manufacturer limits and tolerances from FR.46; not illustrative values or a batch certificate. “Not specified” means the source provides no measurement. PPI nominal values and TA.82 ranges are shown separately.
Results apply only to the samples identified in each report, under the stated test conditions. They are not certification of the entire product range. Laboratory accreditation belongs to the testing laboratory, not Ürosan.
Intertek
RoHS substance testing
TURT240001959 · Jan 9, 2024
Tested sample
26/D SENBR ANT. P.0910231261
Standard / method
2011/65/EU · (EU) 2015/863 · IEC 62321
Reported result
Pass — tested sample only
The tested sample passed the requested RoHS assessment. Cd, Pb, Hg, non-metal Cr(VI), PBB, PBDE and the four listed phthalates were reported as not detected at the laboratory reporting limits; this does not mean zero content.
The tested sample passed the requested RoHS assessment. Cd, Pb, Hg, non-metal Cr(VI), PBB, PBDE and the four listed phthalates were reported as not detected at the laboratory reporting limits; this does not mean zero content.
The tested sample passed the requested RoHS assessment. Cd, Pb, Hg, non-metal Cr(VI), PBB, PBDE and the four listed phthalates were reported as not detected at the laboratory reporting limits; this does not mean zero content.
The tested sample passed the requested RoHS assessment. Cd, Pb, Hg, non-metal Cr(VI), PBB, PBDE and the four listed phthalates were reported as not detected at the laboratory reporting limits; this does not mean zero content.
26 D SENBR black foam, 12.48 mm thick. The five specimens ignited but extinguished before 38 mm. Requirement: ≤102 mm/min. This report does not cover all SENBR grades or establish an EN 45545 / UL94 rating.
Green polyester foam treated with Ultra-Fresh DW-30; samples 01–10
Standard / method
ISO 20743:2013 · Escherichia coli
Reported result
Individual sample results
ISO 20743:2013 assessment after 24 hours at 37 °C. Sample 01 is the reference. Reported reductions: >99.9% for 02–06, 08 and 09; >99.0% for 07 and 10. Some numerical columns are inconsistent; individual values require laboratory clarification. Not a food-contact or migration test.
Submitted by ALPHA ACOUSTIKI LTD. for ISOLFON SEP & POLYFON in 2016. Four specimens did not ignite. No manufacturer is identified; this is not evidence of Ürosan grade certification.
The supplied documents do not include Ürosan ISO 9001, ISO 14001 or ISO 45001 certificates. Current certificates, scope and validity must be confirmed separately. No EN 45545, UL94, VDA 270, food-contact or migration report was supplied.
Test standards by product
Reticulated foam
FR.46 · ISO 845 · ISO 1798 · ISO 2439 · ISO 3386 · ISO 7231 · TA.82
FR grades
FR.46 · FMVSS 302 (26 D SENBR)
Technical polyether
FR.46 · ISO 845 · ISO 3386 · ISO 2439
Converted parts
Dimensions per drawing
Quality process
01
Incoming raw material control
02
In-process control
03
Final inspection
04
Certificate of analysis per shipment
05
Block-level traceability
First-order policy
If a first order misses the agreed specification, we replace it free of charge.
Batch traceability
Coming
Scan the QR code on a label to open the batch record: lot, grade, test results and certificate.